Energy Answers by Tactical Energy Group Podcast Por Daniel Burke arte de portada

Energy Answers by Tactical Energy Group

Energy Answers by Tactical Energy Group

De: Daniel Burke
Escúchala gratis

Energy Answers is the commercial and industrial energy management show from Tactical Energy Group, hosted by Daniel Burke. This series covers the complete C&I energy canon — 100 decisions every plant manager, facilities director, and industrial operator needs to understand: demand charges, power factor, utility rate structures, energy procurement, load management, demand response, backup power, renewable options, submetering, and everything in between. If you manage a facility and energy costs or power reliability are on your radar, this is where you get real answers — no theory, no jargon, no sales pitch on the first visit. New episode every week.

2026 Daniel Burke
Economía Política y Gobierno
Episodios
  • Energy Decision #04 - Power Factor Penalties & Correction Strategies – What Every Operator Must Know
    Apr 18 2026

    Power factor penalties are one of the least understood and most overlooked charges on a commercial and industrial electricity bill — and for facilities running inductive loads like motors, transformers, and HVAC systems, they can add thousands of dollars monthly to a bill the operator has never been shown how to read.

    This is Energy Decision #04 in the complete C&I energy management series from Tactical Energy Group. 100 decisions. Every one that matters.

    In this episode, Daniel Burke covers:

    — What power factor is and how real power (kW), reactive power (kVAR), and apparent power (kVA) create the financial exposure most C&I operators never see coming

    — The three primary utility penalty mechanisms for low power factor: percentage surcharges on demand, excess kVA billing, and kVARh charges

    — and how each inflates your monthly bill

    — Why a facility measuring 1,000 kW of real power at 80 percent power factor may be billed for 1,250 kW of demand and what that costs annually

    — How poor power factor artificially inflates billed demand above metered demand, increasing your all-in cost per kilowatt-hour

    — The real-world benefits of power factor correction: eliminated penalties, reduced kVA demand charges, increased transformer and switchgear capacity, reduced I²R losses, and extended equipment lifespan

    — The four types of correction equipment

    — fixed capacitors, automatic power factor correction banks, detuned filter banks, and active harmonic filters — and how to select the right one for your facility's load profile

    — Why harmonic analysis is non-negotiable before installing any capacitor bank, and what happens when it is skipped

    — The overcorrection risk: why 100 percent power factor is not the target, and why a leading power factor can trigger its own utility penalties

    — The most dangerous and least discussed post-installation failure: capacitor banks off at the breaker while power factor penalties continue to accrue undetected for months

    — Why utilities have a structural financial incentive to never help their C&I customers correct power factor — and what that means for your energy management strategy

    Who this is for: plant managers, facility managers, COOs, maintenance directors, and energy managers at manufacturing plants, chemical facilities, cold storage operations, and large industrial facilities who want to understand whether their utility rate penalizes low power factor and whether correction would materially reduce their monthly electricity costs.

    If you are trying to understand how to effectively identify, calculate, and implement power factor correction strategies to eliminate utility penalties and optimize electricity costs in your facility, this episode is built for you.

    Read the full breakdown on Power Factor Penalties and Correction Strategies at tac-nrg.com/power-factor-penalties-correction.

    If you're an Indiana C&I operator actively evaluating this decision, get your free Energy Decision Blueprint at blueprint.tac-nrg.com.

    Visit tac-nrg.com to learn more and get practical tools for your facilities.

    Más Menos
    39 m
  • Energy Decision #03 - Demand Ratchets Explained: Why One Peak Can Punish You for a Year (Part 1)
    Apr 10 2026

    If you run a plant, hospital, school system, municipality, or large commercial facility and you’ve ever wondered why your billed demand is higher than what the meter shows, this episode is for you. In Part 1 on demand ratchets, we break down what they are, how they actually work on your bill, and why one short peak can inflate your costs for months. By the end, you’ll know when ratchets hurt you, what metrics to watch, and how to start treating them as a manage‑able cost instead of an untouchable mystery.

    Energy Decision Blueprint -- Get It Here: https://tacticalenergygroup.manus.space/

    Más Menos
    24 m
  • Energy Decision #02 -Time-of-Use Rates: When They Actually Save You Money (And When They Don’t)
    Apr 4 2026

    If you run a manufacturing plant, cold storage facility, school system, hospital, municipality, or large commercial operation and you’re being pushed toward a Time-of-Use (TOU) rate, this episode is for you. We’ll decode what TOU really is, when it clearly helps, when it quietly inflates your costs, how to use monitoring to see the truth, and the exact vendor questions that smoke out sloppy proposals. By the end, you’ll know whether TOU is a real play for your facility and what to ask before you sign anything.